Is MSN4600-CS2RC the 200GbE SN4600 model?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
No. CS2RC is the 100GbE SN4600C configuration with 64 QSFP28 cages. The 200GbE VS2RC model is a separate order code with QSFP56 and is listed in the legacy EOL section.
Public references
- Ordering Information | NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual
- Introduction | NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual
How is SN4600C used in NVIDIA’s DGX BasePOD guide?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
The H200/H100 guide uses a pair of SN4600C switches for in-band management and provisioning, with bonded host connections and MLAG. The guide identifies the model family, not the CS2RC airflow suffix.
Public references
- Network Deployment — NVIDIA DGX BasePOD: Deployment Guide Featuring NVIDIA DGX H200/H100 Systems
- Networking — NVIDIA DGX BasePOD: Deployment Guide Featuring NVIDIA DGX H200/H100 Systems
Can SN4600C have a documented storage-network role?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
NVIDIA’s BasePOD hardware overview lists SN4600C for Ethernet-attached storage and QM9700 for the alternative InfiniBand storage fabric. This establishes a design option, not a guarantee for every storage array or workload. Validate the storage vendor’s networking requirements.
Public references
What airflow and power configuration does CS2RC specify?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
The exact ordering row specifies C2P airflow and two AC power supplies. The forward-airflow CS2FC is a different order code. Match fans and supplies to the chassis and airflow requirement.
Public references
- Ordering Information | NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual
- Accessory and Replacement Parts | NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual
Is the typical 466 W figure a rack-power maximum?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
No. The SN4600C figure is typical power measured with passive cables under the stated ATIS condition. Facilities sizing must account for the intended configuration, optics, power feeds and redundancy rather than treating that typical figure as a maximum.
Public references
What software and lifecycle does NVIDIA list for CS2RC?
Applicable canonical content subjects: 920-9N302-00R7-0C0.
The ordering table specifies Cumulus Linux and marks CS2RC MP (Mass Production). This does not establish the supplied unit’s installed release, software entitlement, stock or warranty. Preserve those as separate commercial and deployment checks.