Technical selection

100GbE QSFP28 active optical cables technical selection questions

Technical evaluation questions with variant-specific scope and sources.

Editorial Team•2026年10月10日
100GbE QSFP28 active optical cables technical selection questions

100GbE QSFP28 active optical cables technical selection questions

These questions are prepared from the cited technical documentation and clearly scoped owner inputs. They are not a measured frequency ranking. Keep the applicability line with each answer; do not transfer board, cooling, crypto, protocol, cable length or firmware facts between variants.

What do the -C variants support?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

The exact C015, C020 and C050 ordering and release rows identify 100GbE. Broad MFA1A00 family text also mentions EDR, but the exact -C rows do not establish EDR support.

Public references

How are the three variants different?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

They are the 15 m, 20 m and 50 m versions of a QSFP28-to-QSFP28 active optical cable. Use the exact length-specific model in the cable schedule.

Public references

What are the lane and power characteristics?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

The Ethernet design uses four 25G-NRZ lanes. With all lanes retimed, the specification gives 2.2 W typical and 2.5 W maximum per end.

Public references

What lifecycle context belongs on the page?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

The exact three OPNs are EOL [HVM] in CX7 v28.50.1002. That is a manufacturer lifecycle statement, not a conclusion about a particular seller’s stock or the condition of a supplied unit.

Public references

Where does forward error correction take place?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

The FAQ places FEC in the switch and network adapter. Match the supported endpoint configuration; a cable does not independently fix a FEC mismatch.

Public references

Why can a cable have two minimum bend radii?

Applicable canonical content subjects: 980-9I13A-00C015, 980-9I130-00C050, 980-9I13F-00C020.

The connector exit generally needs a larger bend radius than the cable body. Follow the exact assembly drawing and leave adequate space behind the rack door.

Public references